Request A Quote From Test Boring Services, Inc.

Looking to have Test Boring Services help you complete your next project? Our professional and knowledgeable team will review your request and contact you as soon as possible.

Thank you for choosing Test Boring Services, Inc.

Click here to download our Quote Request Form

Once complete, please send an email with your completed document to jrselvoski@testboringservices.com. Thank you.

Request for Quotation

*Indicates Required Fields
Client Name *
Request Date *
Please Respond By *

This sheet will be used for utility clearance (PA ONE CALL, Miss Utility, etc.) and will be utilized by the foreman as a project guide – please be as specific as possible.

Quick Job Specifics (check all that apply)

Level Grass Lot
Level Asphalt, Gravel, or Concrete Lot
Inside (width clearance _____ ft./height clearance _____ft.)
Weekend
Slight Slope
Steep Slope (1:1, 2:1, 3:1, ____, ____, ____)
Contamination Concern
Union
Non-Union
Water Hauler Needed
Wetland Concerns
Special Specs. (attached if necessary)
Wooded (hand clearing with chainsaw needed)
Wooded (dozer needed)
Reduced Workday/Second Shift
(____A.M./P.M. to ____ A.M./P.M.)
Special Instrumentation
Low Overhead
Drillers Boring Logs
Comments
Project Name Project No.
Project Manager Contact No.
Field Representative Contact No.

Site Location:

State
County
City / Twp. / Borough
Physical Address
Nearest Intersecting Street
GPS
Specific Site Direction

Please include existing landmarks, be descriptive in directions from cross streets (i.e.-travel 450 ft. north from intersection to site access on left – travel on access road for about 200 ft. to first staked boring on right, etc.)…the more SPECIFIC detail the better.
Will the work be done on public property? Yes No Street Sidewalk
Will the work be done on private property? Yes No

Are the borings staked?

Yes No
If NO, when?

STATE LAWS REQUIRE ALL BORINGS TO BE STAKED IN WHITE PRIOR TO PLACING A PA ONE CALL/MISS UTILITY/OHIO ONE CALL/ETC.
Please mark with white paint on road surfaces and with a wood stake and white ribbon on off road surfaces. On projects that are very far off the road or in highly wooded areas – please mark the roadway and a path showing utility locators where to enter the site, etc.

Are private utilities involved?

Yes No
Private Utility Contact

Private utility lines are the responsibility of the property owner and are not the responsibility of one call locators or TBS, Inc.

Type of Unit Required

TRACK TRUCK TRAILER Soil Scout Big Beaver Excavator Dozer

Click here for descriptions and pictures of equipment.

Project Information

When is your ideal start date?
Purpose of Drilling Geotechnical Environmental
Drilling Methods Hollow Stem Augering Rock Coring Air Rotary Casing Advancer
Other
Do we have permission to access the site? Yes No
Work Times (6:30, 7:00, 7:30, 8:00 AM – 3:00, 3:30, 4:00, 4:30, 5:00 PM) AM - PM
Site Specific Training/Meeting Yes No
Insurance Requirements
MPT (Maintenance Protection of Traffic) or Pedestrian Requirements – SIGNAGE ONLY Yes No
MPT (Maintenance Protection of Traffic) or Pedestrian Requirements – FLAGPERSONS Yes No

Soil Sampling

Yes No
No. of Borings
Max. Distance Between Borings
Soil Sampling Method Continuous SPT 3’ Centers 5’Centers NO SPT
OTHER
Anticipated Max. Depth of Soil per boring
Estimated Total Quantity of Soil Drilling
No. of Bag Samples
No. of Shelby Tubes

Rock Coring

Yes No
No. of Borings
Anticipated max. Depth of Rock per boring
Est. Total Quantity of Rock Coring
Coring Method NQ2 HQ
Other
Cuttings Removal Water Compressed Air
Water on Site None Pond/Steam
Other
Distance to Water from Borings 200’ 400’ 600’ 800’ 1000’ Other

Reclamation

Backfill Hole with Cement Bentonite Grout Cuttings Tremie
Other
Patch Type None Concrete Asphalt
Other

Environmental Details:

Monitoring Devises Piezometer Monitoring Wells Inclinometers Other
LEVEL PPE D C B A
Decon Required Yes No
Comments/Method
Decon onsite required (between samples and holes) Yes No
Decon Pad Yes No
Required Boring Size
Well Size 2" 4" Other
Installation Notes/Procedures


(If available, please include any specs or installation directions.)
Well Development Yes No
Screen Slot Size
Screen Length
PVC Schedule
40 80
Other
Sand Size
Coarse Fine
Other
Bentonite Seal
Protective Covers Standup Flushmount None Other
Protective Pads 2x2x4 2x2x6 Other
HASP in Place? Yes No  If yes, then please attach a copy.
DOT Containers/Drums Yes No How many?
Additional Comments/Remarks *


DO NOT FORGET TO INCLUDE: Boring Plan, and Overview Map of Site to show general area and direction of site.

Website Builder